{"id":4770,"date":"2026-10-07T09:00:00","date_gmt":"2026-10-07T09:00:00","guid":{"rendered":"https:\/\/sinobreaker.com\/?p=4770"},"modified":"2026-07-30T01:42:56","modified_gmt":"2026-07-30T01:42:56","slug":"stainless-steel-vs-polycarbonate-distribution-boxes-outdoor-industrial-selection","status":"publish","type":"post","link":"https:\/\/sinobreaker.com\/pt\/stainless-steel-vs-polycarbonate-distribution-boxes-outdoor-industrial-selection\/","title":{"rendered":"Stainless Steel vs Polycarbonate Distribution Boxes: Outdoor Industrial Selection"},"content":{"rendered":"<h2>Quick Takeaway<\/h2>\n<ul>\n<li>Confirm the applicable solar DC duty before selection.<\/li>\n<li>Record inspection and test evidence.<\/li>\n<li>Keep acceptance documents with the equipment record.<\/li>\n<\/ul>\n<p>Outdoor power distribution is rarely a simple enclosure choice. Rain, UV exposure, washdown, corrosion, impact, condensation, cable entry quality, and maintenance access all affect long-term reliability. For buyers comparing a **stainless steel vs polycarbonate distribution box**, the right decision depends on the actual installation environment, not only on whether the enclosure is \u201cmetal\u201d or \u201cplastic.\u201d<\/p>\n<p>For Sinobreaker Waterproof Distribution Box applications, both stainless steel and polycarbonate can be suitable when the enclosure design, sealing system, accessories, and installation method match the site conditions. The key is to evaluate the full enclosure assembly and the operating environment before selecting the material.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/sinobreaker.com\/wp-content\/uploads\/2026\/07\/fig-01-35.webp\" alt=\"Waterproof Distribution Box: engineering anatomy\" \/><\/figure>\n<h2>Why Material Choice Matters for a Waterproof Distribution Box<\/h2>\n<p>A Waterproof Distribution Box protects electrical components from water, dust, mechanical contact, and environmental degradation. In outdoor industrial projects, the enclosure is part of the safety and reliability system, not just a container.<\/p>\n<p>IEC 62208:2023 applies to empty enclosures before the incorporation of switching and control components, including enclosures for indoor or outdoor low-voltage assemblies. This means selection should support the characteristics and tests of the complete enclosure, not simply rely on the shell material name.<\/p>\n<p>In practical terms, stainless steel and polycarbonate should be compared across:<\/p>\n<ul>\n<li>Water ingress resistance<\/li>\n<li>Corrosion resistance<\/li>\n<li>UV and weathering performance<\/li>\n<li>Mechanical strength and impact resistance<\/li>\n<li>Electrical insulation behavior<\/li>\n<li>Weight and installation convenience<\/li>\n<li>Heat, condensation, and ventilation needs<\/li>\n<li>Maintenance and lifecycle cost<\/li>\n<\/ul>\n<p>A well-designed polycarbonate enclosure may outperform a poorly specified stainless enclosure in some locations. Likewise, stainless steel may be the safer long-term choice in harsh corrosive or high-impact industrial environments.<\/p>\n<h2>Stainless Steel Distribution Boxes<\/h2>\n<p>Stainless steel distribution boxes are widely used in demanding outdoor and industrial applications because they provide high mechanical strength, corrosion resistance, and long service life when correctly specified.<\/p>\n<h3>Strengths of Stainless Steel<\/h3>\n<p>Stainless steel performs well where the enclosure may face physical impact, aggressive cleaning, industrial pollution, or long-term outdoor exposure. It is commonly selected for factories, utilities, transport infrastructure, coastal facilities, wastewater plants, and heavy equipment areas.<\/p>\n<p>Key advantages include:<\/p>\n<ul>\n<li>High mechanical durability<\/li>\n<li>Strong resistance to deformation<\/li>\n<li>Good corrosion resistance with the correct grade<\/li>\n<li>Suitability for hose-down or washdown environments when properly sealed<\/li>\n<li>Professional appearance for exposed industrial installations<\/li>\n<li>Good performance in many high-temperature or rugged locations<\/li>\n<\/ul>\n<p>ABB\u2019s stainless-steel enclosure catalogue identifies outdoor protection against hose-directed water and corrosion for applicable enclosure constructions. However, stainless performance still depends on the grade, surface finish, sealing design, accessories, and environmental exposure.<\/p>\n<h3>Limitations of Stainless Steel<\/h3>\n<p>Stainless steel is not automatically corrosion-proof. In coastal, chemical, fertilizer, marine, food-processing, or wastewater environments, the wrong grade or finish may still suffer staining, pitting, or crevice corrosion.<\/p>\n<p>Important limitations include:<\/p>\n<ul>\n<li>Higher material and fabrication cost<\/li>\n<li>Greater weight than polycarbonate<\/li>\n<li>Potential conductivity, requiring proper grounding and bonding<\/li>\n<li>Possible surface corrosion if the wrong grade is selected<\/li>\n<li>Heat absorption in direct sunlight<\/li>\n<li>Need for careful maintenance in aggressive atmospheres<\/li>\n<\/ul>\n<p>Schneider Electric publishes a dedicated selection guide for stainless-steel enclosures intended for aggressive environments, reinforcing that stainless selection must be linked to the actual corrosive exposure and maintenance conditions rather than a general preference for metal.<\/p>\n<h2>Polycarbonate Distribution Boxes<\/h2>\n<p>Polycarbonate distribution boxes are popular for outdoor electrical distribution because they are lightweight, corrosion-resistant, non-conductive, and easy to install. For many outdoor commercial and light industrial applications, a quality polycarbonate Waterproof Distribution Box provides a practical balance of protection and cost.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/sinobreaker.com\/wp-content\/uploads\/2026\/07\/fig-02-35.webp\" alt=\"Waterproof Distribution Box: test or measurement\" \/><\/figure>\n<h3>Strengths of Polycarbonate<\/h3>\n<p>Polycarbonate is valued for its impact resistance and electrical insulation properties. It does not rust, which makes it attractive for humid outdoor sites, light industrial facilities, control stations, farms, telecom installations, and building services.<\/p>\n<p>Key advantages include:<\/p>\n<ul>\n<li>Lightweight handling and wall mounting<\/li>\n<li>Non-conductive enclosure body<\/li>\n<li>No red rust corrosion<\/li>\n<li>Good impact resistance in suitable formulations<\/li>\n<li>Easier drilling and modification than metal<\/li>\n<li>Lower installed weight on panels, frames, or poles<\/li>\n<li>Competitive cost for many outdoor projects<\/li>\n<\/ul>\n<p>Eaton describes a reinforced-polycarbonate Type 4X enclosure as lightweight, non-conductive, and impact-resistant, with stated outdoor UV and water-exposure credentials. These are product-specific documented properties, not automatic guarantees for every polycarbonate enclosure.<\/p>\n<h3>Limitations of Polycarbonate<\/h3>\n<p>Polycarbonate quality varies significantly. Outdoor performance depends on resin formulation, UV stabilization, wall thickness, gasket design, hinge design, latch quality, and certification claims.<\/p>\n<p>Potential limitations include:<\/p>\n<ul>\n<li>UV degradation if the material is not properly stabilized<\/li>\n<li>Lower rigidity than stainless steel in some large sizes<\/li>\n<li>Possible cracking under chemical exposure<\/li>\n<li>Lower resistance to vandalism or heavy mechanical abuse<\/li>\n<li>Thermal expansion differences compared with metal<\/li>\n<li>Reduced suitability near extreme heat sources<\/li>\n<\/ul>\n<p>For outdoor industrial selection, buyers should verify that the polycarbonate distribution box is intended for outdoor service and has documented performance against water, UV, impact, and temperature requirements.<\/p>\n<h2>Stainless Steel vs Polycarbonate Distribution Box: Selection Factors<\/h2>\n<p>The best way to compare a **stainless steel vs polycarbonate distribution box** is to match each material to the real installation environment. Below are the most important engineering and purchasing factors.<\/p>\n<h3>Water Ingress and Sealing<\/h3>\n<p>Waterproof performance depends on the enclosure design, gasket system, door compression, cable glands, drainage approach, and installation workmanship.<\/p>\n<p>For outdoor Waterproof Distribution Box use, consider:<\/p>\n<ul>\n<li>Expected rain direction and wind pressure<\/li>\n<li>Hose-down or washdown requirements<\/li>\n<li>Splash exposure from machines or vehicles<\/li>\n<li>Cable gland quality and entry location<\/li>\n<li>Door gasket compression after repeated opening<\/li>\n<li>Condensation risk inside the box<\/li>\n<\/ul>\n<p>Stainless steel can be excellent for hose-directed water environments when the enclosure construction is designed for that duty. Polycarbonate can also perform well outdoors when the box has a reliable gasket, secure cover, and suitable cable entry protection.<\/p>\n<h3>Corrosion and Chemical Exposure<\/h3>\n<p>Corrosion is one of the main reasons to choose stainless steel carefully or select polycarbonate instead.<\/p>\n<p>Stainless steel is often preferred where physical strength and corrosion resistance are both required. However, the stainless grade matters. For example, many outdoor industrial buyers compare 304 and 316 stainless steel depending on chloride exposure, marine atmosphere, and chemical contact.<\/p>\n<p>Polycarbonate does not rust, but it can be affected by certain solvents, oils, cleaners, and chemicals. If the enclosure will be exposed to fuel, strong alkalis, acids, or industrial cleaning agents, chemical compatibility should be checked before selection.<\/p>\n<h3>UV and Weather Resistance<\/h3>\n<p>Outdoor enclosures face ultraviolet radiation, temperature cycling, rain, dust, and wind. Stainless steel is generally stable under UV exposure, but it may absorb heat in direct sun depending on finish and color.<\/p>\n<p>Polycarbonate must be UV-stabilized for long-term outdoor service. A low-quality indoor plastic box used outdoors may become brittle, yellowed, or cracked over time. For outdoor projects, choose a polycarbonate Waterproof Distribution Box with documented outdoor suitability.<\/p>\n<h3>Mechanical Impact and Abuse<\/h3>\n<p>In high-traffic industrial zones, mechanical strength may be decisive. Forklift movement, tool impact, vibration, unauthorized access, and accidental knocks can shorten enclosure life.<\/p>\n<p>Stainless steel is usually preferred for:<\/p>\n<ul>\n<li>Heavy industrial workshops<\/li>\n<li>Public or semi-public outdoor areas<\/li>\n<li>Transport and infrastructure sites<\/li>\n<li>Locations with frequent impact risk<\/li>\n<li>Installations requiring high tamper resistance<\/li>\n<\/ul>\n<p>Polycarbonate is suitable where impact exposure is moderate and the enclosure is properly mounted. Reinforced polycarbonate designs can offer strong impact performance, but the exact rating should be verified by product documentation.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/sinobreaker.com\/wp-content\/uploads\/2026\/07\/fig-03-35.webp\" alt=\"Waterproof Distribution Box: application context\" \/><\/figure>\n<h3>Electrical Safety and Conductivity<\/h3>\n<p>Polycarbonate is non-conductive, which can simplify certain installations and reduce the risk of the enclosure body becoming energized. This is one reason polycarbonate boxes are widely used for control, communications, and light distribution applications.<\/p>\n<p>Stainless steel is conductive. When used for electrical distribution, it must be properly bonded and grounded according to the project\u2019s electrical code and installation requirements. This is not a disadvantage when correctly installed, but it must be included in the design and inspection process.<\/p>\n<h3>Weight, Installation, and Maintenance<\/h3>\n<p>Polycarbonate distribution boxes are easier to carry, position, drill, and mount. This can reduce installation time, especially for pole-mounted, wall-mounted, or elevated outdoor applications.<\/p>\n<p>Stainless steel boxes are heavier and may need stronger brackets, more robust wall anchors, and additional handling during installation. However, they may offer longer service life in harsh environments, reducing replacement frequency.<\/p>\n<p>Maintenance also differs:<\/p>\n<ul>\n<li>Stainless steel may need cleaning to remove corrosive deposits.<\/li>\n<li>Polycarbonate may need inspection for UV aging, cracking, or gasket compression.<\/li>\n<li>Both require cable gland checks and periodic seal inspection.<\/li>\n<\/ul>\n<h2>Application-Based Recommendations<\/h2>\n<p>Material selection becomes clearer when the project environment is defined. The following scenarios show how Sinobreaker Waterproof Distribution Box buyers can approach the decision.<\/p>\n<h3>Choose Stainless Steel When<\/h3>\n<p>Stainless steel is usually the stronger choice when the site has aggressive environmental or mechanical demands.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Coastal outdoor installations<\/li>\n<li>Chemical or wastewater facilities<\/li>\n<li>Food and beverage washdown areas<\/li>\n<li>Heavy industrial plants<\/li>\n<li>Mining, transport, or utility infrastructure<\/li>\n<li>Public outdoor sites with vandalism risk<\/li>\n<li>Locations requiring strong fire and heat tolerance<\/li>\n<\/ul>\n<p>For these applications, specify the stainless grade, finish, gasket material, cable glands, mounting hardware, and cleaning requirements. Do not select stainless steel only because it sounds stronger; select it because the complete enclosure specification matches the environment.<\/p>\n<h3>Choose Polycarbonate When<\/h3>\n<p>Polycarbonate is often the practical choice where corrosion from rust is a concern, weight matters, and mechanical abuse is moderate.<\/p>\n<p>Typical applications include:<\/p>\n<ul>\n<li>Outdoor building services<\/li>\n<li>Solar and light power distribution<\/li>\n<li>Telecom and communication points<\/li>\n<li>Agricultural control boxes<\/li>\n<li>Pump control and irrigation systems<\/li>\n<li>Small machinery distribution<\/li>\n<li>General outdoor commercial electrical protection<\/li>\n<\/ul>\n<p>For these applications, verify outdoor UV resistance, waterproof rating, impact performance, operating temperature, and compatibility with nearby chemicals.<\/p>\n<h2>Specification Checklist for Sinobreaker Waterproof Distribution Box Buyers<\/h2>\n<p>Before ordering, define the environment and performance expectations clearly. A material-only comparison is not enough.<\/p>\n<h3>Project Conditions to Confirm<\/h3>\n<p>Confirm the following before choosing stainless steel or polycarbonate:<\/p>\n<ul>\n<li>Indoor, outdoor, sheltered, or fully exposed installation<\/li>\n<li>Rain, spray, washdown, or hose-directed water exposure<\/li>\n<li>Coastal, chemical, industrial, agricultural, or clean environment<\/li>\n<li>Required ingress protection level<\/li>\n<li>Ambient temperature and direct sunlight exposure<\/li>\n<li>Internal heat from electrical components<\/li>\n<li>Cable entry direction and gland specification<\/li>\n<li>Need for locks, hinges, windows, or internal mounting plates<\/li>\n<li>Inspection and maintenance interval<\/li>\n<li>Applicable electrical standards and local code requirements<\/li>\n<\/ul>\n<h3>Enclosure Details to Verify<\/h3>\n<p>For a complete Waterproof Distribution Box specification, review:<\/p>\n<ul>\n<li>Enclosure material and grade<\/li>\n<li>Wall thickness and structural design<\/li>\n<li>Door or cover sealing method<\/li>\n<li>Gasket material and compression<\/li>\n<li>Mounting feet or brackets<\/li>\n<li>Cable gland compatibility<\/li>\n<li>UV and weathering credentials<\/li>\n<li>Corrosion or chemical resistance documentation<\/li>\n<li>Impact resistance information<\/li>\n<li>Grounding requirements for metal boxes<\/li>\n<\/ul>\n<p>IEC 62208:2023 reinforces the idea that enclosure suitability is based on defined characteristics and tests of the empty enclosure before components are installed. Therefore, procurement should focus on documented enclosure performance, not only on generic material labels.<\/p>\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/sinobreaker.com\/wp-content\/uploads\/2026\/07\/fig-04-35.webp\" alt=\"Waterproof Distribution Box: supply handover\" \/><\/figure>\n<h2>Cost and Lifecycle Value<\/h2>\n<p>Initial price is only one part of the decision. A lower-cost enclosure can become expensive if it cracks, leaks, corrodes, or requires replacement during production.<\/p>\n<p>Polycarbonate may offer lower installed cost because it is lightweight, easy to mount, and corrosion-free in many normal outdoor settings. Stainless steel may justify its higher cost where long-term durability, impact protection, corrosion resistance, and washdown performance are critical.<\/p>\n<p>When comparing lifecycle value, include:<\/p>\n<ul>\n<li>Purchase price<\/li>\n<li>Installation labor<\/li>\n<li>Mounting hardware<\/li>\n<li>Cable gland and accessory cost<\/li>\n<li>Maintenance frequency<\/li>\n<li>Downtime risk<\/li>\n<li>Replacement interval<\/li>\n<li>Safety and compliance risk<\/li>\n<\/ul>\n<p>For many outdoor industrial projects, the best choice is not the cheapest enclosure. It is the enclosure that protects the internal electrical system for the expected service life with acceptable maintenance.<\/p>\n<h2>Final Selection Guidance<\/h2>\n<p>For Sinobreaker Waterproof Distribution Box selection, stainless steel and polycarbonate both have valid roles.<\/p>\n<p>Choose stainless steel when the installation faces aggressive corrosion, washdown, impact, public access, or heavy industrial conditions. Choose polycarbonate when lightweight handling, electrical insulation, rust-free performance, and cost efficiency are priorities in moderate outdoor environments.<\/p>\n<p>The most reliable decision comes from matching the enclosure material, sealing system, accessories, and documentation to the actual site conditions. In a **stainless steel vs polycarbonate distribution box** comparison, the winning option is the one that fits the environment, standard requirements, and maintenance plan\u2014not simply the one with the stronger-sounding material name.<\/p>\n<h2>FAQ<\/h2>\n<h3>Is stainless steel always better than polycarbonate for outdoor distribution boxes?<\/h3>\n<p>No. Stainless steel is stronger in many harsh industrial environments, but polycarbonate can be the better choice for lightweight, non-conductive, rust-free outdoor installations. The correct option depends on UV exposure, corrosion risk, impact risk, water exposure, and maintenance conditions.<\/p>\n<h3>Can a polycarbonate Waterproof Distribution Box be used outdoors?<\/h3>\n<p>Yes, if it is designed and documented for outdoor use. Buyers should confirm UV resistance, water ingress protection, impact performance, gasket quality, and operating temperature range. Not every polycarbonate enclosure is suitable for long-term outdoor service.<\/p>\n<h3>When should I choose stainless steel for a Waterproof Distribution Box?<\/h3>\n<p>Choose stainless steel for aggressive environments such as coastal sites, chemical plants, washdown areas, heavy industrial zones, public infrastructure, and locations with high impact or vandalism risk. The stainless grade, finish, sealing system, and maintenance plan should match the specific exposure conditions.<\/p>\n<h2>Related Sinobreaker Resources<\/h2>\n<ul>\n<li><a href=\"https:\/\/sinobreaker.com\/waterproof-distribution-box\/\">Sinobreaker resource<\/a><\/li>\n<li><a href=\"https:\/\/sinobreaker.com\/pv-combiner-box\/\">Sinobreaker resource<\/a><\/li>\n<li><a href=\"https:\/\/sinobreaker.com\/dc-switch-disconnector\/\">Sinobreaker resource<\/a><\/li>\n<li><a href=\"https:\/\/sinobreaker.com\/dc-spd\/\">Sinobreaker resource<\/a><\/li>\n<\/ul>\n<h2>Standards Reference<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/67906\" rel=\"noopener\">Applicable authority source<\/a><\/li>\n<\/ul>\n<p><script type=\"application\/ld+json\" data-sinobreaker-schema=\"article\">[{\"@context\":\"https:\/\/schema.org\",\"@type\":\"TechArticle\",\"headline\":\"Stainless Steel vs Polycarbonate Distribution Boxes: Outdoor Industrial Selection\",\"description\":\"Engineering guidance for waterproof distribution box from Sinobreaker.\",\"url\":\"https:\/\/sinobreaker.com\/?p=4770\",\"mainEntityOfPage\":\"https:\/\/sinobreaker.com\/?p=4770\",\"image\":\"https:\/\/sinobreaker.com\/wp-content\/uploads\/2026\/07\/feature-image-35.webp\",\"publisher\":{\"@type\":\"Organization\",\"name\":\"Sinobreaker\",\"url\":\"https:\/\/sinobreaker.com\"}},{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Is stainless steel always better than polycarbonate for outdoor distribution boxes?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Stainless steel is stronger in many harsh industrial environments, but polycarbonate can be the better choice for lightweight, non-conductive, rust-free outdoor installations. The correct option depends on UV exposure, corrosion risk, impact risk, water exposure, and maintenance conditions.\"}},{\"@type\":\"Question\",\"name\":\"Can a polycarbonate Waterproof Distribution Box be used outdoors?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, if it is designed and documented for outdoor use. Buyers should confirm UV resistance, water ingress protection, impact performance, gasket quality, and operating temperature range. Not every polycarbonate enclosure is suitable for long-term outdoor service.\"}},{\"@type\":\"Question\",\"name\":\"When should I choose stainless steel for a Waterproof Distribution Box?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Choose stainless steel for aggressive environments such as coastal sites, chemical plants, washdown areas, heavy industrial zones, public infrastructure, and locations with high impact or vandalism risk. The stainless grade, finish, sealing system, and maintenance plan should match the specific exposure conditions.\"}}]}]<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Quick Takeaway Confirm the applicable solar DC duty before selection. Record inspection and test evidence. Keep acceptance documents with the equipment record. Outdoor power distribution is rarely a simple enclosure choice. Rain, UV exposure, washdown, corrosion, impact, condensation, cable entry quality, and maintenance access all affect long-term reliability. For buyers comparing a **stainless steel vs [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4765,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[37],"tags":[],"class_list":["post-4770","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-waterproof-distribution-box"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/posts\/4770","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/comments?post=4770"}],"version-history":[{"count":1,"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/posts\/4770\/revisions"}],"predecessor-version":[{"id":4771,"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/posts\/4770\/revisions\/4771"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/media\/4765"}],"wp:attachment":[{"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/media?parent=4770"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/categories?post=4770"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sinobreaker.com\/pt\/wp-json\/wp\/v2\/tags?post=4770"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}