Dispositivo de proteção contra surtos de CC para PV (48V-1000V) | DC SPD In 20kA / Imax 40kA

  • ✔ Type 2 DC surge protector (PV system up to 1000 VDC)
  • ✔ Discharge capacity: In 20 kA, Imax 40 kA (8/20 µs)
  • ✔ Fast response <25 ns, low residual voltage
  • ✔ Pluggable cartridge, DIN-rail mount, thermal disconnector
  • ✔ Optional remote alarm contacts
  • ✔ Standard: IEC 61643-31
Obter uma cotação
Categoria:

DC Surge Protective Device (DC SPD) — C40 Series (48V / 220V / 500V / 600V / 1000V)

The C40 series DC surge protective device (SPD) is engineered for photovoltaic DC buses and other DC networks. It uses instalação paralela to provide reliable surge suppression without affecting normal system operation.

Principais recursos

  • Wide clearance & creepage distance; withstands high voltage; suitable for high-altitude areas.
  • Pluggable modular cartridge; standard 35mm DIN-rail mounting.
  • High-quality lightning-proof components for stable performance.
  • Hot-melt + over-current dual protection circuit.
  • Status window: green = normal, red = replacement required.
  • Low residual voltage, fast response <25ns, strong discharge capability.
  • Opcional remote signaling contact for SCADA/BMS.

Main Technical Parameters — C40 Series

Modelo Max Continuous Operating Voltage
Uc (DC)
Corrente de descarga nominal
In (8/20 μs)
Corrente máxima de descarga
Imáximo (8/20 μs)
Nível de proteção de tensão
Para cima
Tempo de resposta Ambiente operacional Seção transversal de L/N Classe de proteção Outline Size (mm)
C40-48 48V DC 20 kA 40 kA ~ 350 V <25 ns -40 °C ~ +80 °C ≥ 10 mm² IP20 36 × 66 × 90
C40-220 220V DC 20 kA 40 kA ~ 1.8 kV <25 ns -40 °C ~ +80 °C ≥ 10 mm² IP20 36 × 66 × 90
C40-500 500V DC 20 kA 40 kA ~ 2,5 kV <25 ns -40 °C ~ +80 °C ≥ 10 mm² IP20 36 × 66 × 90
C40-600 600V DC 20 kA 40 kA ~ 2,8 kV <25 ns -40 °C ~ +80 °C ≥ 10 mm² IP20 36 × 66 × 90
C40-1000 1000V CC 20 kA 40 kA ~ 3,5 kV <25 ns -40 °C ~ +80 °C ≥ 10 mm² IP20 54 × 66 × 90

Notes: Values follow the supplied datasheet. Update cells if your latest engineering data differs.

Desenhos

Dimensão

DC SPD C40 series dimension drawing


Diagrama de fiação (paralelo)

DC SPD C40 series wiring diagram (parallel connection)


PERGUNTAS FREQUENTES

Which systems is the C40 series designed for?
Photovoltaic DC buses and other DC networks from 48V to 1000V. Select the model by matching Uc.
How do I choose among C40-48 / 220 / 500 / 600 / 1000?
Choose by the max continuous voltage Uc of your DC bus, then verify surge ratings (In/Imax) and target a low Para cima.
Where should the SPD be installed?
Install at the DC combiner/distribution panel with parallel wiring, short leads, and a reliable PE bar. Follow the diagram.
Is the module replaceable and is remote signaling available?
Yes. The cartridge is pluggable for quick replacement; an optional alarm contact can be wired to SCADA/BMS.
What environmental and wiring requirements apply?
Temperatura operacional −40°C ~ +80°C, cross-section of L/N ≥10mm², gabinete IP20.
How should surge protection be coordinated?
Coordinate with upstream over-current protection (e.g., DC fuse/breaker) and inverter limits to ensure selectivity and safety.

Avaliações

Não há avaliações ainda.

Seja o primeiro a avaliar “DC Surge Protective Device for PV (48V–1000V) | DC SPD In 20kA / Imax 40kA”

O seu endereço de e-mail não será publicado. Campos obrigatórios são marcados com *