Dispositivo di protezione dalle sovratensioni DC per PV (48V-1000V) | SPD DC In 20kA / Imax 40kA

  • ✔ Type 2 DC surge protector (PV system up to 1000 VDC)
  • ✔ Discharge capacity: In 20 kA, Imax 40 kA (8/20 µs)
  • ✔ Fast response <25 ns, low residual voltage
  • ✔ Pluggable cartridge, DIN-rail mount, thermal disconnector
  • ✔ Optional remote alarm contacts
  • ✔ Standard: IEC 61643-31
Richiedi un preventivo
Categoria:

DC Surge Protective Device (DC SPD) — C40 Series (48V / 220V / 500V / 600V / 1000V)

The C40 series DC surge protective device (SPD) is engineered for photovoltaic DC buses and other DC networks. It uses installazione in parallelo to provide reliable surge suppression without affecting normal system operation.

Caratteristiche principali

  • Wide clearance & creepage distance; withstands high voltage; suitable for high-altitude areas.
  • Pluggable modular cartridge; standard 35mm DIN-rail mounting.
  • High-quality lightning-proof components for stable performance.
  • Hot-melt + over-current dual protection circuit.
  • Status window: green = normal, red = replacement required.
  • Low residual voltage, fast response <25ns, strong discharge capability.
  • Opzionale remote signaling contact for SCADA/BMS.

Main Technical Parameters — C40 Series

Modello Max Continuous Operating Voltage
Uc (DC)
Corrente di scarica nominale
In (8/20 μs)
Corrente di scarica massima
Imassimo (8/20 μs)
Livello di protezione della tensione
Su
Tempo di risposta Ambiente operativo Sezione trasversale di L/N Classe di protezione Outline Size (mm)
C40-48 48V DC 20 kA 40 kA ~ 350 V <25 ns -40 °C ~ +80 °C ≥ 10 mm² IP20 36 × 66 × 90
C40-220 220V DC 20 kA 40 kA ~ 1.8 kV <25 ns -40 °C ~ +80 °C ≥ 10 mm² IP20 36 × 66 × 90
C40-500 500V DC 20 kA 40 kA ~ 2,5 kV <25 ns -40 °C ~ +80 °C ≥ 10 mm² IP20 36 × 66 × 90
C40-600 600V DC 20 kA 40 kA ~ 2,8 kV <25 ns -40 °C ~ +80 °C ≥ 10 mm² IP20 36 × 66 × 90
C40-1000 1000V CC 20 kA 40 kA ~ 3,5 kV <25 ns -40 °C ~ +80 °C ≥ 10 mm² IP20 54 × 66 × 90

Notes: Values follow the supplied datasheet. Update cells if your latest engineering data differs.

Disegni

Dimensione

DC SPD C40 series dimension drawing


Schema di cablaggio (parallelo)

DC SPD C40 series wiring diagram (parallel connection)


FAQ

Which systems is the C40 series designed for?
Photovoltaic DC buses and other DC networks from 48V to 1000V. Select the model by matching Uc.
How do I choose among C40-48 / 220 / 500 / 600 / 1000?
Choose by the max continuous voltage Uc of your DC bus, then verify surge ratings (In/Imax) and target a low Su.
Where should the SPD be installed?
Install at the DC combiner/distribution panel with parallel wiring, short leads, and a reliable PE bar. Follow the diagram.
Is the module replaceable and is remote signaling available?
Yes. The cartridge is pluggable for quick replacement; an optional alarm contact can be wired to SCADA/BMS.
What environmental and wiring requirements apply?
Temperatura di esercizio −40°C ~ +80°C, cross-section of L/N ≥10mm², recinto IP20.
How should surge protection be coordinated?
Coordinate with upstream over-current protection (e.g., DC fuse/breaker) and inverter limits to ensure selectivity and safety.

Recensioni

Ancora non ci sono recensioni.

Recensisci per primo “DC Surge Protective Device for PV (48V–1000V) | DC SPD In 20kA / Imax 40kA”

Il tuo indirizzo email non sarà pubblicato. I campi obbligatori sono contrassegnati *