DC Switch Disconnector for PV / ESS / Wind (1000V & 1500V)

Arc-safe isolation · IEC 60947-3 · IP66 enclosure · 2P/4P options

DC Switch disconnector

DS1 Series DC Switch Disconnector

Our DS1 series covers indoor and outdoor use with two configurations: DS1-32 (IP20, panel-mount) and DS1-32EL (IP66, enclosed). Both comply with IEC 60947-3 and provide arc-safe isolation for PV strings and inverter cabinets.

  DS1-32 (IP20) DS1-32EL (IP66)
Mounting Panel-mount (indoor) Enclosed, wall-mount (outdoor)
Protection IP20 IP66, UV-resistant
Typical environment Inverter/combiner, indoor Rooftop PV, outdoor combiner
Notes Compact footprint Lockable handle, harsh-weather ready

Not sure which to choose? See the Selection Guide

Standards: IEC 60947-3 compliant; DC-PV2/DC-21B utilization categories (model dependent).

Datasheets: Full specifications available in the Download Center.

Key Features of DS1 Series DC Switch Disconnector

Designed for PV, ESS and industrial DC isolation. Choose between compact panel-mount (IP20) or rugged enclosed outdoor (IP66) to match your installation.

High Voltage DC

Up to 1000 V DC; suitable for PV strings and inverter cabinets.

Indoor / Outdoor

DS1-32 (IP20) panel-mount or DS1-32EL (IP66) enclosed for outdoor use.

IEC 60947-3

Compliant DC isolator categories (e.g., DC-PV2/DC-21B, model-dependent).

Maintenance Safety

Visible isolation, lockable rotary handle; arc-safe design.

Datasheets & compliance details available in the Download Center.

Where the DS1 Series Fits

The DS1 series provides safe DC isolation across common PV and ESS scenarios. Choose IP20 for protected indoor panels, or IP66 for harsh outdoor conditions.

pv combiner dc isolator switch indoor IP20

PV Combiner / Inverter Side (Indoor)

Panel-mount isolator for array inputs and inverter DC side. Compact footprint, quick wiring, visible OFF position.

Typical pick: DS1-32 (IP20)

Selection tips →
outdoor rooftop pv dc isolator IP66

Outdoor PV Strings / Rooftop Arrays

Weather-sealed isolator near string inputs or combiner boxes. UV & rain resistant, lockable handle for maintenance.

Typical pick: DS1-32EL (IP66)

Selection tips →
ess battery rack dc disconnector IP66

ESS Battery Racks / Wind Nacelle Cabinets

Emergency DC isolation for battery racks and nacelle cabinets. Vibration-resistant enclosure; fast, visible disconnection.

Typical pick: DS1-32EL (IP66)

Selection tips →
Reliable DC Protection for Your Energy Systems Request Your Free Sample

Technical Specifications of DC Switch Disconnectors

Summary of key parameters for the DS1 series. Not sure which to choose? See the Selection Guide.

Technical comparison between DS1-32 (IP20) and DS1-32EL (IP66) DC switch disconnectors.
Parameter DS1-32 (IP20) DS1-32EL (IP66)
Rated voltage Up to 1000 V DC Up to 1000 V DC
Rated current 32 A 32 A
Poles / configurations 2P / 4P 2P / 4P
Utilization category* DC-PV2 / DC-21B (model dependent) DC-PV2 / DC-21B (model dependent)
Ingress protection IP20 (indoor) IP66 (outdoor, UV-resistant)
Mounting Panel-mount Enclosed, wall-mount
Handle / locking Rotary, lockable (LOTO) Rotary, lockable (LOTO)
Operating temperature −25 °C ~ +55 °C (typ.) −25 °C ~ +55 °C (typ.)
Typical environment Inverter / combiner (indoor) Rooftop PV, outdoor combiner
Notes Compact footprint Harsh-weather ready

Standards: Complies with IEC 60947-3. For CE marking information, see EU CE Marking.

System protection: Often paired with DC fuses and DC SPDs for comprehensive PV safety.

* Utilization category depends on configuration and rating. See datasheets for full details in the Download Center.

Selection Guide · How to Choose the Right DC Switch Disconnector

Use this quick guide to match the DS1 series to your PV, ESS or wind system. Still have doubts? See our contact page for expert advice.

Condition Recommended Model Why?
Indoor combiner box / inverter cabinet DS1-32 (IP20) Compact size, panel-mount, cost-effective
Outdoor PV string combiner / rooftop array DS1-32EL (IP66) Weather-sealed enclosure, UV resistant, easy wall-mount
Systems with arc flash & surge risk Pair with DC Fuses & DC SPDs Enhanced protection & compliance
Wind turbine nacelle / ESS battery container DS1-32EL (IP66) Sealed, resistant to vibration & dust

⚡ For large-scale PV plants, always combine switch disconnectors with proper DC fuses and surge protective devices.

Talk to a Technical Advisor

Installation & Safety Notes for DC Switch Disconnectors

Ensure reliable performance and operator safety with proper installation and maintenance practices.

Pre-installation Checklist

  • Confirm correct model: IP20 indoor or IP66 outdoor.
  • Verify conductor size, insulation class, and UV-resistant cables for outdoor use.
  • Prepare LOTO devices and perform insulation resistance tests.

Wiring & Torque

  • Follow polarity markings and maintain minimum bending radius.
  • Ensure stress relief on all terminations.
  • Tighten terminals to recommended torque values (see datasheet).

Commissioning

  • Visually confirm complete isolation before energizing.
  • Conduct load break tests for each string or battery rack.
  • Apply system labeling for PV array, ESS, or inverter cabinet identification.

System Protection Pairing

For complete DC protection, pair switch disconnectors with DC fuses and DC surge protective devices, in accordance with IEC 60947-3.

Global Delivery, Warranty & Certifications

We provide fast worldwide shipping, export-grade packaging, and dependable after-sales support.

Lead Time

Standard models ship within 7–15 days. Bulk orders by schedule.

Packaging

Shock-proof inner + export cartons; wooden crate optional for sea freight.

Logistics

Worldwide via DHL / UPS / FedEx or air/sea freight with tracking.

Warranty

24–36 months limited warranty with technical support.

Compliant with IEC 60947-3 • CE • RoHS

Frequently Asked Questions

A DC switch disconnector isolates the DC circuit for maintenance or emergency shutdown. It ensures operator safety and system protection in PV arrays, battery racks, and DC distribution cabinets.
They are commonly installed at the DC side of PV arrays, ESS enclosures, or inverter cabinets, allowing safe isolation during inspection or fault conditions.
Yes, our products comply with IEC 60947-3, and carry CE, TUV, and RoHS certifications for global applications.
We provide both IP20 indoor versions and IP66 weatherproof enclosures, suitable for outdoor PV farms and harsh industrial environments.
Yes, for complete system protection they are recommended to be used alongside DC fuses and DC surge protective devices.