Wind Power DC Surge Protective Device (DC SPD) | Wind Turbine DC Protection 500V/660V/690V/1000V

Wind power DC surge protective device (DC SPD) for wind turbine DC buses — nacelle, pitch, yaw and converter cabinets. Parallel installation, pluggable DIN-rail module, fast response <25ns, optional remote signaling. Options for 500V / 660V / 690V / 1000V DC.

Get A Quotation
Category:

Wind Power DC Surge Protective Device (DC SPD)

This wind power DC surge protective device protects wind turbine DC buses in the nacelle, pitch and yaw systems, and converter cabinets.
Designed for wind farm DC surge protection, it uses parallel installation to shunt lightning-induced and switching surges without interrupting operation.
The pluggable DIN-rail module supports fast maintenance, with an optional remote signaling contact for SCADA/BMS.

Key Features for Wind Turbine DC Systems

  • Purpose-built wind turbine DC surge protector for nacelle, pitch/yaw drives, and converter DC cabinets.
  • Parallel connection; fast response <25 ns and low residual voltage to protect sensitive electronics.
  • Pluggable module on 35 mm DIN-rail for quick replacement and minimal downtime.
  • Dual protection circuit (hot-melt + over-current); clear status window (green = normal / red = replace).
  • Rugged construction for wind farm environments: −40 °C ~ +80 °C, enclosure IP20.
  • Optional remote signaling for integration with wind SCADA/BMS.

Main Technical Parameters — Wind Power DC SPD Series

ModelRate Operating Voltage
Un (VDC)
Max Continuous Voltage
Uc (VDC)
Operation Voltage
(VDC)
Nominal Discharge Current
In (8/20 μs)
Max Discharge Current
Imax (8/20 μs)
Voltage Protection Level
Up (V)
Response Time
(ns)
Operating EnvironmentCross Section of L/N
(mm²)
Protection ClassOutline Size
(mm)
C40-660660690110020 kA40 kA~ 2.3 kV<25−40 °C ~ +80 °C≥10IP2054 × 66 × 90
C40-690690750120020 kA40 kA~ 2.5 kV<25−40 °C ~ +80 °C≥10IP2054 × 66 × 90
B80-660660690110040 kA80 kA~ 2.8 kV<25−40 °C ~ +80 °C≥10IP2054 × 66 × 90
B80-690690750120040 kA80 kA~ 3.0 kV<25−40 °C ~ +80 °C≥10IP2054 × 66 × 90
B100-660660690110060 kA120 kA~ 3.3 kV<25−40 °C ~ +80 °C≥10IP2081 × 66 × 90
B100-690690750120060 kA120 kA~ 3.5 kV<25−40 °C ~ +80 °C≥10IP2081 × 66 × 90
B150-660660690110080 kA150 kA~ 3.6 kV<25−40 °C ~ +80 °C≥10IP2081 × 66 × 90
B150-690690750120080 kA150 kA~ 3.8 kV<25−40 °C ~ +80 °C≥10IP2081 × 66 × 90

Note: Select by wind turbine bus voltage (Un/Uc) and surge rating (In/Imax). Keep leads short, ensure reliable DC grounding, and coordinate with upstream DC fuse/breaker.

Drawings

Dimension

wind turbine DC surge protective device dimension drawing

Wiring Diagram (Parallel)

wind turbine DC SPD wiring diagram (parallel)

FAQ

What is a wind power DC surge protective device?
A DC SPD engineered for wind turbine DC buses (nacelle, pitch, yaw, converter cabinets), installed in parallel to shunt lightning and switching surges safely to ground.
Which DC voltage levels are supported?
Options include 500V / 660V / 690V / 1000V DC. Match Un/Uc to the wind turbine bus and verify the required surge ratings (In/Imax).
Does it support remote monitoring?
Yes. An optional dry-contact output can be integrated into wind farm SCADA/BMS for alarms and maintenance planning.
What are the wiring and environmental requirements?
Keep leads short to minimize Up; conductor cross-section ≥10 mm²; enclosure IP20; operating temperature −40 °C ~ +80 °C.
Where is it installed inside the turbine?
Typically on a 35 mm DIN-rail inside the nacelle or converter DC cabinet, coordinated with the upstream DC fuse/breaker for selectivity.

Reviews

There are no reviews yet.

Be the first to review “Wind Power DC Surge Protective Device (DC SPD) | Wind Turbine DC Protection 500V/660V/690V/1000V”